Difficulty

Moderate

Steps

8

Time Required

                          35 minutes            

Sections

1

  • Angelcare AC401 Baby Monitor Disassembly
  • 8 steps

Flags

Member-Contributed Guide

An awesome member of our community made this guide. It is not managed by iFixit staff.

  • BackAngelcare AC401 Baby Monitor

  • Full Screen

  • Options

  • History

  • Save to Favorites

  • Download PDF

  • Edit

  • Translate

  • Get Shareable Link

  • Embed This Guide

  • Notify Me of Changes

  • Stop Notifications

Introduction

two rechargeable battery’s exploded, the acid was around an electric power cable. so there were two problems :

1 bad connection

2 battery damage.

we will check also the second unit.

What you need

Step 1

              Angelcare AC401 Baby Monitor Disassembly               
  • first remove the 2 screws at the green plastic plate.

first remove the 2 screws at the green plastic plate.

1024

Step 2

  • remove the plastic plate ( battery compartment)
  • you’ll see that there are 2 more screws. Remove them.

remove the plastic plate ( battery compartment)

you’ll see that there are 2 more screws. Remove them.

Step 3

  • now gently remove the green plastic plate arrounf the baby monitor ( arround the screen) use a spudger to click it open.

now gently remove the green plastic plate arrounf the baby monitor ( arround the screen) use a spudger to click it open.

Step 4

  • now open the monitor by clicking it open or slide it open. Sometimes its easier to use a spudger.
  • be carefull for the electric wires.

now open the monitor by clicking it open or slide it open. Sometimes its easier to use a spudger.

be carefull for the electric wires.

Step 5

  • 2 battery’s were exploded so the acid was on the black electric power wire.
  • use a cotton swab with a little bit of destilled water.

2 battery’s were exploded so the acid was on the black electric power wire.

use a cotton swab with a little bit of destilled water.

Step 6

  • remove the 2 PCB’s by removing the screws shown in the picture.

remove the 2 PCB’s by removing the screws shown in the picture.

Step 7

  • pull the first PCB up and remove the screws of the second PCB.
  • after removing the two PCB’s, clean the acid on the PCB.
  • after cleaning the PCB’s put it al together again.

pull the first PCB up and remove the screws of the second PCB.

after removing the two PCB’s, clean the acid on the PCB.

after cleaning the PCB’s put it al together again.

Step 8

              second unit               
  • first remove the battery lid. 1 screw.
  • slide it out like you see in picture
  • remove battery’s

first remove the battery lid. 1 screw.

slide it out like you see in picture

remove battery’s

To reassemble your device, follow these instructions in reverse order.

Cancel: I did not complete this guide.

                                                                                      6 other people completed this guide.                                             

Author

                                      with 4 other contributors 

                    Kevin D                     

Member since: 05/02/2014

7,090 Reputation

                                      21 Guides authored                  



                       Badges:
                       24







                                                        +21 more badges                           

Pete H - Mar 31, 2015

Reply

Thanks for this. I couldn’t figure out how to get the blue clip off without breaking it to clean some dirt on the screen. Googled it, found this, job done.

Dmitriy N - Aug 2, 2017

Reply

Sometimes the activity of the reference quartz is 11,150 MHz, and the devices do not find each other.

I have so repaired the parent module.

Dmitriy, the city of Volzhsky.

Jan - Aug 17, 2017

Reply

Hi Dimitriy - I am experiencing the issue with not finding devices each other. How have you fix it ? Is it a matter of replacing the reference quartz with new one ?

Terese Rehn - Aug 23, 2017

Reply

Hi. At my Angelcare (AC401) parent unit the screen has slowly become worse and worse. At first, parts of the temperature figures dissapeared, then the symbols around and now I no longer see anything… But the unit still works! (And alert me if the baby’s crying) What do you think, is there anything I can do or do I need to buy a new one?

Eugene - Feb 9, 2018

Hi There. I’m having the same problem. Did you find a fix or did you buy a new unit?