Step 1
Switch to manual mode
- To enable manual mode, flip the switch to “Manual Mode”
- LCD screen will turn on
To enable manual mode, flip the switch to “Manual Mode”
LCD screen will turn on
1024
Step 2
Restart the sampling program
- Press On then press Start Sampling
- Press Enter
Press On then press Start Sampling
Press Enter
Step 3
Select bottle
- Press the number of the bottle you want to sample on
- Press Enter
- LCD should now show which bottle it will take a sample in
Press the number of the bottle you want to sample on
LCD should now show which bottle it will take a sample in
Step 4
Switch to autonomous mode
- To enable autonomous mode, flip switch to “Node Trigger Mode”
- LCD should turn off
- If the autosampler is to be remotely triggered, avoid using the ON/OFF button to power off the sampler.
To enable autonomous mode, flip switch to “Node Trigger Mode”
LCD should turn off
If the autosampler is to be remotely triggered, avoid using the ON/OFF button to power off the sampler.
Now the sampler is ready to be triggered remotely by an open-storm sensor node.