Difficulty
Moderate
Steps
7
Time Required
30 minutes
Sections
1
- Faulty Resistor
- 7 steps
Flags
2
In Progress
This guide is a work in progress. Reload periodically to see the latest changes!
Member-Contributed Guide
An awesome member of our community made this guide. It is not managed by iFixit staff.
BackBosch AL 1860 CV
Full Screen
Options
History
Save to Favorites
Download PDF
Translate
Get Shareable Link
Embed This Guide
Notify Me of Changes
Stop Notifications
Introduction
Credits: https://www.eevblog.com/forum/beginners/…
Step 1
Remove the AC plug
- Remove the AC plug
Remove the AC plug
1024
Step 2
Open the charger
- Open the charger (remove 4 Philips screws)
Open the charger (remove 4 Philips screws)
Step 3
Find Resistor R3
- Localize resistor R3
Localize resistor R3
Step 4
Remove circuit board from case
- Detach the circuit board from the housing (4 plastic tabs)
- Caution: Capacitor (150uF/400V) may still be charged!!!
Detach the circuit board from the housing (4 plastic tabs)
Caution: Capacitor (150uF/400V) may still be charged!!!
Step 5
Obtain new resistor
- Obtain new 220k Ohm 2W resistor
Obtain new 220k Ohm 2W resistor
Step 6
Desolder R3
- Resistor R3 needs to be desoldered
Resistor R3 needs to be desoldered
Step 7
Replace resistor R3
- Solder resistor R3 in place
Solder resistor R3 in place
Follow the steps in reverse order to reassemble the device
Cancel: I did not complete this guide.
One other person completed this guide.
oldturkey03 is helping us fix the world! Want to contribute? Start translating ›