Introduction

What you need

Step 1

              Removing Scanner Header               
  • Twist green section to allow the scanner head to have a full range of motion.

Twist green section to allow the scanner head to have a full range of motion.

1024

Step 2

              Removing Scan Header               
  • To remove scanner head, open it halfway as possible and slide the hinges out of place and the head will be removed.

To remove scanner head, open it halfway as possible and slide the hinges out of place and the head will be removed.

Step 3

              Remove scanner head connection to printer               
  • The panels to expose the cords will become exposed when the head is removed.
  • Pull all colored cords from the printer and unscrew the other wire to be fully removed.
  • Pull the black tab from the printer to remove.

The panels to expose the cords will become exposed when the head is removed.

Pull all colored cords from the printer and unscrew the other wire to be fully removed.

Pull the black tab from the printer to remove.

Step 4

              Removing the bottom screws               
  • Once scanner is free from the printer remove all the screws on the bottom base
  • Use a #2 Philips head screw driver to remove the two 12.1mm screws.

Once scanner is free from the printer remove all the screws on the bottom base

Use a #2 Philips head screw driver to remove the two 12.1mm screws.

Step 5

              Exposing scanner glass               
  • To separate the base from the glass hold upright and separate along the edge where you removed the screws.
  • Use hands to expose the glass.
  • Keep track flat once glass is removed as to not lose little parts.

To separate the base from the glass hold upright and separate along the edge where you removed the screws.

Use hands to expose the glass.

Keep track flat once glass is removed as to not lose little parts.

Step 6

              Replacing scanner glass               
  • Disconnect the glass from the tracks.
  • Remove old or broken glass.
  • Replace with adhesive tape along the bottom of the header and reassemble.

Disconnect the glass from the tracks.

Remove old or broken glass.

Replace with adhesive tape along the bottom of the header and reassemble.

To reassemble your device, follow these instructions in reverse order.

Cancel: I did not complete this guide.

                                                                                      2 other people completed this guide.                                             

Author

                                      with 3 other contributors 

                    George Kielpinski                     

Member since: 10/30/2014

50 Reputation

                                      1 Guide authored                  



                       Badges:
                       8







                                                        +5 more badges                           

Team

                       UMass Dartmouth, Team 4-4, Miles Fall 2014                        

                                                  Member of UMass Dartmouth, Team 4-4, Miles Fall 2014 



                    UMASSD-MILES-F14S4G4                     


                                            3 Members                     


                                            5 Guides authored