You’ve tried everything… No matter what you do, you can’t get your compressor to turn on.
As obvious as this suggestion may be… just check the On/Off switch. It should be in the ON position.
Check the circuit breaker and fuse corresponding to the outlet you are using. Make sure the circuit breaker has not been tripped or a fuse blown.
This model is designed to automatically shut off the pump motor at a designated pressure. Try Releasing air in order to reduce the pressure and allow the motor to turn on to rebuild tank pressure.
The thermal overload switch may be triggered. Allow the compressor to cool in open area for at least 30 minutes. Try not to run the motor in excess of 100 degrees Fahrenheit.
Replace the pressure switch. See the replacement guide for step-by-step instruction.
If your tank pressure does not hold when the compressor motor turns off, the tank has some kind of leaky component.
If the drain valve is loose, tighten the valve. Check the connections between hoses and fittings with soapy water to detect possible leaks after tightening.
If the check valve is leaking, replace with a new check valve. See the replacement guide for step-by-step instructions. Check the connections between the hoses and fittings with soapy water to detect possible leaks after replacing the valve.
The compressor is designed to shut off at a specific pressure inside the tank. Basically, the compressor is unable to accumulate enough pressure to properly function.
See user manual for the pressure rating and the compressor limitations.
Check the connections between the hoses and fittings with soapy water to detect possible leaks.
Replace entire pump assembly.
The continuous accumulation of pressure will eventually discharge through the safety valve if the pressure levels reach the critical pressure threshold for this compressor.
Replace the pressure switch with a new component.
Replace safety valve with a genuine replacement component. This is critical because if you do not use the correctly manufactured valve, pressure can exceed expected limits and become potentially hazardous to the user.
“Common causes for excessive or random starting and stopping can be attributed to lack of regular maintenance of the compressor.''
Drain the tank more regularly.
Check the connections between the hoses and fittings with soapy water to detect any possible leaks
If you come across an issue not mentioned in this troubleshooting page or need to purchase replacement parts for your machine, visit eReplacementParts.com