What you need
Step 1
EFS 18-135mm Lens Main Board
- First, detach the lens by pressing and holding the release button highlighted in the picture.
- Next, grab the lens and rotate it counter-clockwise when looking at the camera.
- Finally, when the camera stops rotating, pull the lens away from the camera.
First, detach the lens by pressing and holding the release button highlighted in the picture.
Next, grab the lens and rotate it counter-clockwise when looking at the camera.
Finally, when the camera stops rotating, pull the lens away from the camera.
1024
Step 2
- Remove the four 5.5-mm Phillips #000 screws for the lens mount ring (silver ring).
- Remove the two 4-mm Phillips #000 screws mounting the main board connector.
- This guide involves removing a lot of very small screws so be sure to have a magnet board to keep track of them.
Remove the four 5.5-mm Phillips #000 screws for the lens mount ring (silver ring).
Remove the two 4-mm Phillips #000 screws mounting the main board connector.
This guide involves removing a lot of very small screws so be sure to have a magnet board to keep track of them.
Step 3
- Using a spudger, pull the connector loose from the barrel switch ring assembly.
- Set barrel switch ring assembly to the side.
Using a spudger, pull the connector loose from the barrel switch ring assembly.
Set barrel switch ring assembly to the side.
Step 4
- Using a spudger, pull the five connectors out of their housing.
- Use very gentle pressure when pulling connectors out of the lens main board, as they tend to break easily.
Using a spudger, pull the five connectors out of their housing.
Use very gentle pressure when pulling connectors out of the lens main board, as they tend to break easily.
Step 5
- Remove the two 4-mm Phillips #000 main board mounting screws.
- Remove the main board from the lens with your hand.
- The main board is now successfully removed from the lens.
Remove the two 4-mm Phillips #000 main board mounting screws.
Remove the main board from the lens with your hand.
The main board is now successfully removed from the lens.
To reassemble your device, follow these instructions in reverse order.
Cancel: I did not complete this guide.
One other person completed this guide.
Author
with 2 other contributors
Paul
Member since: 03/12/2018
762 Reputation
3 Guides authored
Badges:
11
+8 more badges
Team
University of Memphis, Team S2-G5, Kim Spring 2018
Member of University of Memphis, Team S2-G5, Kim Spring 2018
UM-KIM-S18S2G5
3 Members
11 Guides authored